Food & Beverage

GE Pro LA Series

60hz Reverse Osmosis Machines 10-100 m3/h

The PRO platform is a range of pre-engineered RO machines and supporting components like multi-media filters, carbon filters, water softeners, chemical feed systems, tanks, and pumps for the building blocks of a full-scale configurable water system. With decades of engineering and manufacturing experience worldwide, we offer superior standardization and optimization of RO system design.

diagram of the reverse osmosis process
Standard Features
  • AB PanelView 300 3.0-inch Monochrome Display
  • Touch Screen Controls
  • AB Micrologix PLC Communication: RS232
  • 4-20 mA Instruments Displayed on Instrument Center
  • NR-10 Electrical Panel
Options & Upgrades
  • AB PanelView Plus 700 7.0-inch Color Display
  • Text and Pictorial Operating Screens
  • Touch Screen Controls
  • AB CompactLogix PLC Communication: Ethernet
  • 4-20 mA Instruments on Touch Screen
  • Primary and final Pressure Transmitters
  • Conductivity Transmitter on Feed
  • RO permeate Flush on Shutdown
  • NR-10 Electrical Panel
  • NR-13 compliance
  • PH meter on RO Feed
  • GE Fanuc PLC Control Package
  • Membrane Options:
  • 400 Square Foot Elements
  • High Rejection Elements
  • Low Energy Elements
  • Motor Starter
  • Variable Frequency Drive
  • ORP meter
  • pH meter (basic)
  • PRO Multi-Media filters
  • PRO Activated Carbon and Softeners
  • PRO Clean-in-Place units
  • PRO Chemical Feed Systems
  • Transfer Pumps and Storage Tanks
Downloads
Equipment Characteristics
Model Pro-11-LA Pro-23-LA Pro-34-LA Pro-45-LA Pro-68-LA Pro-102-LA
Permeate Rate2 11 m3/hr 23 m3/hr 34 m3/hr 45 m3/hr 70 m3/hr 100 m3/hr
Concentrate Rate 4 m3/hr 7.5 m3/hr 11 m3/hr 15 m3/hr 23 m3/hr 34 m3/hr
Concentrate Recycle 2.3 m3/hr 2.3 m3/hr NA 3.4 m3/hr NA NA
Feed Rate 15 m3/hr 30.5 m3/hr 45 m3/hr 60 m3/hr 93 m3/hr 134 m3/hr
operating parameters
Design Recovery1 75% 75% 75% 75% 75% 75%
Design Temperature 20°C 20°C 20°C 20°C 20°C 20°C
Nominal Rejection 97-99% 97-99% 97-99% 97-99% 97-99% 97-99%
Operating Temperature 2-30°C 2-30°C 2-30°C 2-30°C 2-30°C 2-30°C
System Inlet Pressure 2-4 bar 2-4 bar 2-4 bar 2-4 bar 2-4 bar 2-4 bar
materials of construction
Enclosure Nema 12 Nema 12 Nema 12 Nema 12 Nema 12 Nema 12
Clamps/Fittings Zinc-plated Zinc-plated Zinc-plated Zinc-plated Zinc-plated Zinc-plated
Frame Painted Carbon Steel Painted Carbon Steel Painted Carbon Steel Painted Carbon Steel Painted Carbon Steel Painted Carbon Steel
Low-Pressure Piping Schedule 80 PVC Schedule 80 PVC Schedule 80 PVC Schedule 80 PVC Schedule 80 PVC Schedule 80 PVC
High-Pressure Piping 316 Stainless Steel, Sch. 10 316 Stainless Steel, Sch. 10 316 Stainless Steel, Sch. 10 316 Stainless Steel, Sch. 10 316 Stainless Steel, Sch. 10 316 Stainless Steel, Sch. 10
pumps & motors
Model SS8512 SS12509 SS24008 AS40406 AS40407 AS40407
Manufacturer GE/Tonkaflo GE/Tonkaflo GE/Tonkaflo GE/Tonkaflo GE/Tonkaflo GE/Tonkaflo
Quantity 1 1 1 1 1 1
Motor Power & Type 15 kW (20hp) TEFC 22 kW (30 hp) TEFC 37.3 kW (50 hp) TEFC 37.3 kW (50 hp) TEFC 45 kW (60 hp) TEFC 45 kW (60 hp) TEFC
Installed Power 15 kW 22 kW 37.3 kW 37.3 kW 45 kW 90 kW
Design Flow Rate 17 m3/hr (75 gpm) 30.2 m3/hr (150 gpm) 45.4 m3/hr (200 gpm) 68.1 m3/hr (300 gpm) 90.9 m3/hr (400 gpm) 136.2 m3/hr (600 gpm)
Design Boost Pressure 15.9 Bar (230 psig) 14.5 Bar (210 psig) 15.9 Bar (230 psig) 13.8 Bar (200 psig) 12.8 Bar (185 psig) 15.9 Bar (230 psig)
membrane elements & housings
Membranes Quantity 12 24 36 48 72 108
Membrane Housing Style 4 element long, 4 port 4 element long, 4 port 6 element long, 4 port 4 element long, 4 port 6 element long, 4 port 6 element long, 4 port
Banking Arrangement 1:1:1 3:2:1 3:2:1 6:4:2 6:4:2 9:6:3
cartridge filtration
Housing Model HX-0740-3.0-V-316 HX-0740-3.0-V-316 HX-0740-3.0-V-316 HX-0740-3.0-V-316 HX-0740-3.0-V-316 HX-0740-3.0-V-316
Housing Quantity 1 1 2 2 3 4
Cartridge Filter Model RO.Zs01-40XK RO.Zs01-40XK RO.Zs01-40XK RO.Zs01-40XK RO.Zs01-40XK RO.Zs01-40XK
Cartridge Filter Length 102 cm (40”) 102 cm (40”) 102 cm (40”) 102 cm (40”) 102 cm (40”) 102 cm (40”)
Cartridge Filter Quantity 7 per housing, 7/change out 7 per housing, 7/change out 7 per housing, 14/change out 7 per housing, 14/change out 7 per housing, 21/change out 7 per housing, 28/change out
installation & utility requirements
Inlet 2.0” flange 3.0” flange 3.0” flange 4.0” flange 4.0” flange 6.0” flange
Permeate 1.5” flange 3.0” flange 3.0” flange 3.0” flange 4.0” flange 6.0” flange
Concentrate 1.0” flange 1.5” flange 1.5” flange 2.0” flange 2.0” flange 3.0” flange
Inlet Water Pressure 2 bar, minimum 2 bar, minimum 2 bar, minimum 2 bar, minimum 2 bar, minimum 2 bar, minimum
Air Pressure 7 bar, oil-free 7 bar, oil-free 7 bar, oil-free 7 bar, oil-free 7 bar, oil-free 7 bar, oil-free
Drain to be Sized for 15 m3/hr (67 gpm) 30 m3/hr (133 gpm) 45.4 m3/hr (200 gpm) 60.6 m3/hr (267 gpm) 91 m3/hr (400 gpm) 136 m3/hr (600 gpm)
Power 380-480 VAC, 3-phase, 60Hz 380-480 VAC, 3-phase, 60Hz 380-480 VAC, 3-phase, 60Hz 380-480 VAC, 3-phase, 60Hz 380-480 VAC, 3-phase, 60Hz 380-480 VAC, 3-phase, 60Hz
Control Circuit 120-220 VAC, 1-phase, 60Hz 120-220 VAC, 1-phase, 60Hz 120-220 VAC, 1-phase, 60Hz 120-220 VAC, 1-phase, 60Hz 120-220 VAC, 1-phase, 60Hz 120-220 VAC, 1-phase, 60Hz
dimensions & weight
Height 193 cm (76”) 193 cm (76”) 193 cm (76”) 193 cm (76”) 193 cm (76”) 193 cm (76”)
Width 117 cm (46”) 117 cm (46”) 117 cm (46”) 203 cm (80”) 203 cm (80”) 203 cm (80”)
Depth 493 cm (194”) 493 cm (194”) 696 cm (274”) 493 cm (194”) 696 cm (274”) 696 cm (274”)
Shipping Weight Estimate 1542 kg (3400 lb) 2040 kg (4500 lb) 2720 kg (6000 lb) 3175 kg (7000 lb) 4305 kg (9500 lb) 6350 kg (14,000 lb)

1Recovery Rate can vary +/- 5%

2Maximum permeate rate listed at design temperature. Permeate rate can be reduced by up to 15%.